Deliver T3, E3, STS-1 or Ethernet signals quickly and cost-effectively with Telect's optical-electrical converters. Choices include T3 or Ethernet modules, protected T3 module sets for additional redundancy, and single-fibre T3 modules that send and receive signals through a single connector. 

Wall-mount systems include one module and a mounting bracket, and require a power supply (see below) if a 48V source is not readily available. 

Features 

  • Deliver DS3s 50km and Ethernet 30km over single mode fibre
  • Extend cross-connects across large offices, campuses, buildings, or in building risers
  • Rapidly deploy DS3 or Ethernet service to remote customers
  • Extend DSL service to additional customers quickly and simply
  • 1RU chassis provides advanced functionality in minimal space
  • Wall mount systems include one module and mounting bracket
  • Mounting brackets suitable for EIA/WECO


Housing for wall mount system

   

 SPECIFICATIONS

 

Electrical Interface

Receive equalization

0 to 900 RG-59 (or equivalent)

Input impedance

75 Ohms

Output impedance

75 Ohms

Monitor level

21 dB +1.5 dB below signal level

Format selection

Manually selected prior to power up

Error rate (maximum)

1x10-10, with 23 dB fiber attenuation, single mode glass fiber, 0 to 50° C

Return loss

< -26 dB 300 kHz to 30 MHz, single module
< -16 dB 300 kHz to 30 MHz, redundant modules

 

Optical Interface

Mode

Single mode or multimode, based on configuration

Range

50 km (19 dB link budget)
30 km Ethernet

Optical source

Laser, 1310 & 1530 nm nominal wavelengths

Spectral width

+50 nm max

Transmit power (nominal)

–11 dBm, into 1 m 9 µm single-mode glass fiber, all-ones electrical signal, 25° C

Transmit power (minimum)

–15 dBm, into 1 m 9 µm single-mode glass fiber, all-ones electrical signal, 0 to 50° C ambient

Extinction ratio

8.2 dB min.

Laser safety

Unconditionally eyesafe laser, IEC 825/CDRH class 1 compliant

Optical receiver

PIN diode and integral amplifier

Receiver range

-8 dBm to -34 dBm
-8 dBm to -31 dBM Ethernet

Link loss budget

19 dB
16 dB Ethernet

Connector

SC or ST

 

T3

Input data rate

44.736 Mbps +100 ppm

Input data format

Bipolar with B3ZS coding

Jitter tolerance

Meets GR-499-CORE requirements

Output data rate

Same as input signal, transmit clock is recovered from input signal

Output data format

Bipolar with B3ZS coding

Output pulse shape

Complies with GR-499-CORE and ANSI T1.102-1993

 

STS-1

Input data rate

51.84 Mbps +100 ppm

Input data format

Bipolar with B3ZS coding

Jitter tolerance

Meets GR-499-CORE requirements

Output data rate

Same as input signal, transmit clock is recovered from input signal

Output data format

Bipolar with B3ZS coding

Output pulse shape

Complies with GR-CORE-253

 

E3

Input data rate

34.368 Mbps +100 ppm

Input data format

AMI with HDB3 coding

Jitter tolerance

Meets ITU-T G.832-1993 requirements

Output data rate

Same as input signal, transmit clock is recovered from input signal

Output data format

AMI with HDB3 coding

Output pulse shape

Complies with ITU-T G.703

 

Ethernet

Protocol

ANSI/IEEE 802.3

Data rate

10/100 Mbps

Signaling

10 base-T, 100 base-TX

Connection rate

Auto negotiate to greatest common denominator of end network interfaces, or manual mode

Segment length

100 m, Cat 5 (shielded or unshielded)

Connector

Shielded RJ45

RJ45 pins

1: Transmit+
2: Transmit-
3: Receive
4: HF Termination
5: HF Termination
6: Receive-
7: HF Termination
8: HF Termination

 

Signal Formats

Transmit frequency

1310 nm for 13/15 Module; 1530 nm for 15/13 Module

Receive frequency

1530 nm for 13/15 Module; 1310 nm for 15/13 Module

 

Remote Alarm Indicators

PWR alarm

Loss of 3.3V on-board power, normally open contact, common output at rear of chassis, “PWR ALARM”

MAJ alarm

Condition determined at power-up, normally open contact, common output at rear of chassis, “MAJ ALARM”

 

Power

Powering architecture

Single DC-DC converter

Redundant power

Chassis accommodate A and B battery inputs; inputs are diode "ORed" on the module

Chassis operating voltage

20 to 60 VDC

Current (maximum)

180mA @ 20 VDC
110mA at 18 VDC per module Ethernet

 

Environmental

Operating temperature range

0 to 50° C ambient

Storage temperature range

–55° C to 85° C

Operating humidity

5 to 95%, noncondensing

Storage humidity

< 95%

Heat dissipation

706W/m2 per meter @ ambient of 19° C (66° F)

Altitude

0–10,000' (3,048 m), operating

 

Redundancy

Active module

Right-hand module, viewed from the front of the chassis, is the factory default

Automatic switch

Switch of data traffic from active to standby modules initiated by detection of loss of optical or electrical signal

Manual switch

Pressing MAN (“Manual”) on active module will force a switchover to the standby data link if the standby modules are installed and functioning properly

Switch timing

< 5 ms, applies to hardware or fiber data link failure

 

Compliance

Agency compliance

NEBS 3
FCC Part 15, Class A
UL/CSA 1950

       

 

 
 